Durable ventricular assistance: from surgical approach to the artificial heart of the future

Analysis and reflections on the presentations on durable ventricular assistance at the XXVIII SECCE Congress, focusing on the debate over the surgical approach for HeartMate 3® implantation and the development of future circulatory support devices

Durable left ventricular assistance has changed profoundly over the past decade. The established role of HeartMate 3® (HM3®) has shifted part of the discussion from survival towards other goals: reducing complications, making implantation less invasive and ensuring that living for years with a ventricular assist device feels progressively less like being connected to a machine.

The ventricular assistance session at the XXVIII SECCE Congress captured this transition well. Dr Daniel Ortiz Berbel and Dr José Manuel Martínez Cereijo defended opposing views on the implantation approach—median sternotomy versus thoracotomy-based techniques—before Dr Cristian Muñoz Guijosa broadened the discussion to the future of surgical treatment for advanced heart failure.

Although these appeared to be separate debates, both converged on the same question: if patients will live increasingly longer with a left ventricular assist device (LVAD), and some will subsequently require another operation or transplantation, should implantation still be viewed as an isolated operation?

1. Sternotomy versus a dual-incision approach: two concepts of safety

Dr Ortiz’s defence of sternotomy centred on three concepts: speed, precision and safety. Full exposure provides control of the apex, ventricular axis and entire outflow graft course, while allowing an immediate response to bleeding, right ventricular failure or the need for concomitant procedures.

This is no minor issue. LVAD implantation has a substantial geometrical component. Incorrect inflow cannula orientation may alter flow patterns and promote suction events or thrombosis, whereas inappropriate outflow graft length or orientation may lead to potentially serious late twisting. Sternotomy allows this geometry to be checked directly before the procedure is completed.

Ortiz also challenged three supposed advantages of less invasive surgery: less right ventricular (RV) failure, bleeding and infection. His central argument was that the literature is heterogeneous and, above all, heavily influenced by patient selection.

RV failure illustrates this problem particularly well. Pericardial preservation and potentially less geometrical distortion have been proposed as protective mechanisms of thoracotomy-based implantation. However, some studies reporting less RV failure include patients requiring concomitant valve procedures or presenting with more complex clinical conditions in the sternotomy group. Direct comparison may therefore attribute to the approach what is actually explained by patient characteristics. Current evidence does not consistently establish that avoiding sternotomy reduces RV failure.

Dr Martínez Cereijo’s position arose from a very different setting: experience at a lower-volume, non-transplant centre involving 15 patients, nine implanted through thoracotomy and six through sternotomy. These were predominantly older patients, with a mean age of approximately 71 years, previously declined for transplantation and mainly in INTERMACS profile 3.

The strongest intraoperative finding was a significant reduction in cardiopulmonary bypass (CPB) time, from 84 to 55 minutes, or approximately 33%. Importantly, no reduction in total operating time was presented. Other outcomes mainly showed trends: less bleeding at 24 hours, no reoperations for bleeding in the thoracotomy group, shorter ventilation and shorter hospital stay, without statistical significance.

The technical explanation is perhaps more interesting than the numbers from a small series. The apical sewing ring can be sutured without CPB and the driveline tunnelled before heparinisation. CPB is thus limited to the stages in which it is genuinely needed. The potential benefit may therefore depend on reorganising the procedure to reduce its physiological impact, rather than simply making a smaller incision.

2. What does the evidence actually tell us?

LATERAL was one of the first robust demonstrations that this concept was feasible. It included 144 patients undergoing HVAD implantation through lateral thoracotomy. This prospective, multicentre, single-arm study reported good clinical outcomes and shorter hospital stays than historical controls. Its main limitation for this discussion is clear: it used a different device from HM3 and did not randomise patients to thoracotomy or sternotomy.

HM3 SWIFT is much more applicable to current practice. It included 102 patients treated at 23 centres using thoracotomy-based techniques and compared them with a matched MOMENTUM 3 cohort. The less invasive approach met non-inferiority for the primary clinical endpoint, with event-free survival of 85.0% versus 86.2%. However, there were no differences in blood product use, adverse events or RV failure, and hospital stay was significantly longer, at 20 versus 17 days.

Its message seems clear: thoracotomy is a safe alternative to conventional HM3® implantation, but the study does not establish superiority.

The systematic review published in 2025 provides a more favourable signal. It included 12 studies and 1448 patients, 584 treated with less invasive strategies and 862 through sternotomy, and found comparable survival, with trends towards shorter intensive care stays, fewer reoperations for bleeding and fewer driveline infections. However, some studies reported longer operating or CPB times with less invasive approaches, and heterogeneity in populations and techniques prevented a robust quantitative synthesis.

This may be the most balanced picture of the available evidence: less invasive implantation no longer needs to establish feasibility; it still needs to establish which patients stand to gain meaningfully from it.

3. Beyond HeartMate 3®

Dr Muñoz Guijosa suggested that the needs of the next LVAD generation fall into two groups. Considerable progress has already been made in miniaturisation, haemocompatibility, some pulsatility and more versatile support. Other goals remain unmet: elimination of the percutaneous driveline, transcutaneous energy transfer, fully implantable devices, autoregulation and remote monitoring.

New developments approach these challenges in very different ways:

– CorHeart 6®, developed in China, primarily represents miniaturisation. Weighing approximately 90 g compared with around 200 g for HM3®, it uses magnetic levitation and can deliver high flows despite its small size.

– BrioVAD®, also developed in China, retains magnetic levitation but uses a larger rotor to generate flow at a lower rotational speed, reducing energy consumption. Its driveline is particularly interesting: approximately 3.3 mm compared with 5.7 mm for HM3®, thinner and more flexible, and designed to address one of the principal weaknesses of permanent support. Following hundreds of implants in China, the INNOVATE programme is evaluating it against HM3® in the United States and Europe.

– CorWave® departs more radically from the conventional rotor concept. It uses a polymer membrane oscillating at high frequency under an electromagnetic field, allowing different flow patterns, including pulsatile flow. Initial clinical development has already begun.

– Other concepts explore solutions even further removed from conventional LVADs. EVAHEART 3® uses hydrodynamic levitation and aims to reduce suction events. FineHeart®’s ICOMS FlowMaker® is a fully intraventricular flow accelerator implanted transapically, synchronised with cardiac contraction and designed to maintain antegrade flow through the aortic valve.

The interest lies less in predicting which will reach the market than in seeing how each attempts to address a different limitation of the same technological model.

4. Beyond the LVAD

Dr Muñoz Guijosa’s presentation extended beyond ventricular assistance. It also covered new cardiac graft preservation systems, donation after circulatory death, biomarkers to reduce reliance on endomyocardial biopsy—particularly donor-derived cell-free DNA, together with gene expression, donor-specific antibodies and Torque Teno Virus—xenotransplantation and new targets related to ischaemia–reperfusion injury.

Perhaps the most thought-provoking question was whether transplantation should remain the first option in a young patient.

The argument was straightforward. Transplantation starts the “immunosuppression clock” on day one, whereas current HM3® support allows prolonged survival. A future strategy might use an LVAD first and reserve transplantation for a later stage, aiming to extend the patient’s overall survival. This is not yet an established strategy, but it introduces a different way of thinking about treatment sequencing.

Meanwhile, the total artificial heart continues to evolve. After decades of attempts and numerous abandoned devices, SynCardia® remains the historical reference, while new projects aim to overcome its limitations. BiVACOR® uses magnetic levitation and a single moving part with impeller blades on both sides to drive the pulmonary and systemic circulations simultaneously, and has already reached initial human implantation. Emperor® and Realheart® represent other approaches towards fully implantable biventricular support.

COMMENTARY:

The debate between sternotomy and a dual-incision approach risks oversimplification. Current evidence supports safe thoracotomy-based implantation with equivalent survival in appropriately selected patients. The most recent meta-analysis also suggests potentially meaningful perioperative benefits. However, universal reductions in RV failure, bleeding or infection cannot be claimed, and HM3 SWIFT reminds us that a smaller incision does not automatically make a better operation.

There is another argument, already raised by Dr Martínez Cereijo, that extends well beyond immediate recovery: the patient whose LVAD is not intended as destination therapy. For someone who may later undergo transplantation, avoiding an initial sternotomy could offer a strategic advantage. Transplant surgeons know how complex resternotomy can become in an LVAD recipient: dense adhesions, the RV lying close to the sternum, CPB, the outflow graft, bleeding risk and the need for rapid vascular control before adequate exposure has even been achieved.

The EACTS consensus already recognised left thoracotomy as an alternative in patients with previous cardiac surgery. This becomes more important if support duration continues to increase. Preserving the mediastinum may offer limited value to an older patient receiving an LVAD as definitive treatment, but much more to a young patient whose therapeutic course is unlikely to end with the first implant. At that point, the approach becomes part of a lifetime treatment strategy, extending beyond a discussion of incision length.

Perhaps we should abandon the label “minimally invasive”. What matters is the overall impact of the procedure and the options it preserves for the future, rather than the length of the incision.

From this perspective, a one-third reduction in CPB time, as observed in Dr Martínez Cereijo’s experience, deserves attention despite coming from a small series. The patient who will return to the operating theatre may nevertheless be an even more important consideration.

In destination therapy, sternotomy may continue to offer a combination of speed, exposure, precision and rescue capability that is difficult to surpass. As expected support duration increases, however, the choice of approach should also incorporate each patient’s anticipated therapeutic course. The implantation route may depend as much on what we expect to do in five years as on what we need to do today.

This connects directly with the final part of the session. If future LVADs further reduce complications, eliminate the driveline and enable prolonged support with better quality of life, the boundary between “bridge” and “definitive therapy” will become less distinct. Even the traditional transplant–LVAD sequence may need reconsideration in selected young patients.

For now, HM3® remains the benchmark against which all new pumps are compared. The real turning point will probably come when we can eliminate the percutaneous connection and safely transmit energy across the skin, rather than merely producing a slightly smaller or more haemocompatible device.

On that day, ventricular assistance will have begun to address the much harder challenge of living for years with a mechanically assisted heart, beyond the task of pumping blood.

REFERENCE:

Ortiz D. In Favor of Median Sternotomy. Mesa Asistencia Ventricular. XXVIII Congreso SECCE, Vigo.

Martínez Cereijo JM. In Favor of Minimally Invasive Approaches. Mesa Asistencia Ventricular. XXVIII Congreso SECCE, Vigo.

Muñoz Guijosa C. Future directions in surgical therapy of heart failure: from durable LVADs to heart transplantation and beyond. Mesa Asistencia Ventricular. XXVIII Congreso SECCE, Vigo.

Potapov EV, Antonides C, Crespo-Leiro MG, et al. 2019 EACTS Expert Consensus on long-term mechanical circulatory support. Eur J Cardiothorac Surg. 2019;56(2):230-270. doi:10.1093/ejcts/ezz098.

McGee E Jr, Danter M, Strueber M, et al. Evaluation of a lateral thoracotomy implant approach for a centrifugal-flow left ventricular assist device: the LATERAL clinical trial. J Heart Lung Transplant. 2019;38(4):344-351. doi:10.1016/j.healun.2019.02.002.

Turtabayev B, Joshibayev S, Kervan U, et al. Minimally invasive left ventricular assist device implantation: a systematic review of current evidence on clinical outcomes and surgical approaches. Med Sci (Basel). 2025;13(3):173. doi:10.3390/medsci13030173.

SUBSCRIBE TO OUR MONTHLY NEWSLETTER..
XXVIII Resident Course
Get to know our magazine

Comparte esta información